Which bitumen grade for your climate? Penetration and viscosity grades compared
Use the grade your project specification names. If you can choose, IS 73:2013 (Clause 5) matches viscosity grades to the 7-day average maximum air temperature: VG10 below 30 °C, VG20 30–38 °C, VG30 38–45 °C and VG40 above 45 °C. Among penetration grades, the harder 40/50 suits hotter roads and the softer 80/100 cooler ones.
Key facts
- IS 73:2013 has four viscosity grades (VG10, VG20, VG30, VG40). Clause 5 recommends each for a band of 7-day average maximum air temperature, taken over a period of not less than 5 years from the start of the design period.
- Penetration grades are named by needle penetration at 25 °C in tenths of a millimetre (ASTM D5). A lower number means a harder bitumen.
- ASTM D946 lists the penetration grades 40–50, 60–70, 85–100, 120–150 and 200–300. The trade name 80/100 is closest to ASTM 85–100.
- A penetration grade and a viscosity grade are not interchangeable by name. Only a test report to the standard named in the contract proves compliance.
- Performance grades (AASHTO M 320) name pavement temperatures directly: PG 76-22 is for a high pavement design temperature of 76 °C and a low of −22 °C.
What does IS 73 say about grade and air temperature?
IS 73:2013 classifies paving bitumen into four grades by absolute viscosity at 60 °C and recommends each grade for a range of design air temperature. The air temperature is the 7-day average maximum, taken over at least 5 years from the start of the design period. A hotter site calls for a stiffer grade.
Source: IS 73:2013, Clause 5 (grades and air temperature) and Table 1 (absolute viscosity, penetration). HOMAN supplies VG10, VG30 and VG40.
How do 40/50, 60/70 and 80/100 compare?
Unlike IS 73, ASTM D946 does not set grade-by-temperature bands in its requirements. The rule buyers use is the hardness ladder: the lower the penetration, the stiffer the bitumen, so harder grades go to hotter climates and softer grades to cooler ones. Check the grade against the specification of the road authority first.
Source: ASTM D946 Table 1 (penetration ranges; retained penetration after the thin-film oven test, ASTM D1754). The last column is qualitative guidance, not a requirement of the standard.
Is VG30 the same as 60/70, and VG40 the same as 40/50?
Not by definition. IS 73 grades bitumen by viscosity at 60 °C; ASTM D946 grades it by penetration at 25 °C. The IS 73:2013 penetration minimums (45 for VG30, 35 for VG40) overlap the 60/70 and 40/50 ranges, which is why buyers compare them. A 60/70 lot only counts as VG30 if a test report shows it meets every VG30 limit. The full comparison is in Bitumen 60/70 vs VG30.
When should you look at performance grades (PG) instead?
When the specification is written to AASHTO M 320. A PG name gives the high and low pavement design temperatures the binder is graded for, so PG 76-22 is graded for 76 °C and −22 °C. HOMAN supplies PG 70-16, PG 76-10 and PG 76-22; see performance grade bitumen.
How HOMAN tests and documents each lot
HOMAN has been active since 2016, with trade desks in Tehran and Shenzhen, and exports to buyers in 11 countries. Every lot is lab-tested in Bandar Abbas before shipment. Pre-shipment inspection is carried out by SGS or Geochem, as the buyer chooses. A Certificate of Analysis (COA) is issued for each order lot and tied to the batch number on the packaging.
Test reports to the buyer's required standard, including ASTM and IS 73. We quote EXW, FOB or CFR, with a minimum order of one container.
Frequently asked questions
Which bitumen grade is best for hot climates?
For viscosity grades, IS 73:2013 recommends VG40 where the 7-day average maximum air temperature is above 45 °C and VG30 for 38–45 °C. Among penetration grades, harder grades such as 40/50 are used for hotter conditions. Always follow the grade named in your project specification.
What does 60/70 mean in bitumen?
It is a penetration grade. A standard needle (100 g, 5 seconds, 25 °C, ASTM D5) sinks 60 to 70 tenths of a millimetre into the sample. Lower numbers mean harder bitumen.
What is the 7-day average maximum air temperature in IS 73?
It is the design air temperature IS 73:2013 uses to recommend a grade. The note to Clause 5 says it is the 7-day average maximum air temperature for a period of not less than 5 years from the start of the design period.
Sources
- Bureau of Indian Standards, IS 73:2013 Paving Bitumen — Specification (Fourth Revision): Foreword, Clause 5 (Grades), Clause 7 (Sampling), Clause 8.2 (Marking), Table 1 (Requirements) and Table 2 (Scale of sampling).
- ASTM International, ASTM D946/D946M, Standard Specification for Penetration-Graded Asphalt Binder for Use in Pavement Construction (current edition D946/D946M-25a), Table 1.
- ASTM test methods named in the text: D5 (penetration), D36 (softening point), D92 (flash point, Cleveland open cup), D2042 (solubility in trichloroethylene), D2170 and D2171 (kinematic and absolute viscosity), D1754 (thin-film oven test) and D2872 (rolling thin-film oven test).
- AASHTO M 320, Standard Specification for Performance-Graded Asphalt Binder.